Subscribe to ExpertReview

The latest research, meeting updates and CME, in your inbox.

AI in healthcare · Research

AI tools may shorten treatment times and boost functional independence in large vessel occlusion stroke.

25 Nov 2026Neurology
Share

Artificial intelligence (AI) implementation in large vessel occlusion stroke reduced computed tomography angiography (CTA)‑to‑puncture and door‑to‑puncture times and increased 90‑day functional independence without raising adverse events.

Stylized blue human brain with glowing orange neural activity and digital glitch effects

Background

AI tools were evaluated for workflow efficiency, treatment timing and clinical outcomes in major cerebral vessel occlusion stroke.

Methods

Observational studies that reported workflow, treatment, safety or functional outcomes after introducing AI‑based tools in suspected or confirmed large vessel occlusion stroke were included, and extracted data comprised thrombolysis rates, CTA‑to‑arterial puncture time, door‑to‑puncture time, endovascular treatment (EVT) access, reperfusion success and symptomatic intracerebral haemorrhage, mortality and functional independence at 90 days were extracted. Random‑effects models computed pooled mean differences or risk ratios with 95% CI.

Results

Thirteen studies met the eligibility criteria. AI implementation was associated with a mean CTA‑to‑puncture time difference of –40.20 minutes (95 % CI –66.41 to –13.99; P<0.01), and door‑to‑puncture time showed a mean difference of –23.17 minutes (95 % CI –38.71 to –7.63; P<0.01). Thrombolysis administration showed no significant difference (RR 0.79; 95 % CI 0.57‑1.09; P=0.15). EVT access was unchanged (RR 0.97; 95 % CI 0.66‑1.44; P=0.89). Reperfusion success showed a non‑significant trend (RR 1.06; 95 % CI 1.00–1.12; P=0.06). Symptomatic intracerebral haemorrhage risk was similar (RR 0.63; 95 % CI 0.30–1.35; P=0.23). Mortality was not significantly altered (RR 0.72; 95 % CI 0.38–1.37; P=0.32). Functional independence (modified Rankin Scale 0–2) at 90 days improved (RR 1.55; 95 % CI 1.12–2.15; P=0.008).

Conclusions

AI tools shortened key treatment intervals and increased the proportion of patients achieving functional independence, with no significant difference in adverse event rates.

References

  1. Fernandes JV, Pereira MA, Gonçalves OR, et al. Artificial intelligence for the detection of large vessel occlusion stroke and workflow optimization: a systematic review and meta-analysis. J Neurosurg Sci. 2026;70(5):421-429. doi:10.23736/S0390-5616.26.06694-4 DOI

Medically reviewed by Stijn van den Borne on 25 Nov 2026